Reference

Cleanrooms: definition, standards and classes

A cleanroom is a room with controlled airborne particle concentrations. Temperature, humidity, pressure differentials and airflow are controlled as required. In French standards, the term is ‘salle propre’ (NF EN ISO 14644); ‘salle blanche’ is the common alternative. Both describe the same technical concept.

Two French terms for cleanrooms

‘Salle blanche’ is the historical French translation of cleanroom , popularised by electronics and microtechnology. ‘Salle propre’ is the term adopted by French standards and pharmaceutical guidance. Our French expertise pages use the standards terminology; this reference explains both terms.

ISO 14644 classes and GMP grades

ISO 14644-1 classifies cleanrooms by maximum airborne particle concentrations for specified particle sizes and occupancy states. EU GMP Annex 1 defines grades A to D for sterile medicinal product manufacture. The table below shows particle classification equivalences at rest; GMP grades also include additional requirements.

ISO 14644 classes and EU GMP Annex 1 grades at rest
ISO class (at rest) GMP grade Typical use
ISO 5Grade ACritical zone: aseptic filling under unidirectional airflow
ISO 5Grade BBackground environment for a grade A zone outside an isolator. For isolators, the background should generally be at least grade C for open isolators and grade D for closed isolators, justified by risk assessment and documented in the CCS.
ISO 7Grade CLess critical stages in the manufacture of sterile products
ISO 8Grade DLess critical stages in the manufacture of sterile products

References: NF EN ISO 14644-1 and 14644-2, EU GMP Annex 1 (2022 revision), and PIC/S PE 010 for medicinal product preparation in healthcare establishments.

From project to operation: key stages

  • Design: target classifications, flows of personnel, materials and waste, and the air handling concept.
  • Qualification: DQ, IQ, OQ, PQ — filter integrity testing, particle counting, air change rates, airflow visualisation and recovery time.
  • Monitoring: particle and microbiological sampling plans, pressure differential monitoring and trend analysis.
  • Ongoing compliance: periodic requalification, change control and operator training in cleanroom behaviour.

Frequently asked questions

What is the difference between ‘salle blanche’ and ‘salle propre’?

Both French terms refer to a cleanroom. ‘Salle blanche’ is common usage; ‘salle propre’ is the term used in NF EN ISO 14644. Both describe a room with controlled airborne particle concentrations, with temperature, humidity, pressure and airflow controlled as required.

How is a cleanroom classified?

ISO 14644-1 defines airborne particle concentration limits per cubic metre for specified particle sizes and occupancy states. In pharmaceutical manufacturing, these ISO classes are considered alongside grades A to D in EU GMP Annex 1.

How often should a cleanroom be requalified?

Requalification frequency is primarily risk-based. EU GMP Annex 1 sets maximum intervals: 6 months for grades A and B, and 12 months for grades C and D. Requalification is also required after changes assessed as significant through change control. This is supported by grade- and risk-appropriate monitoring: particles and microbiological monitoring throughout critical operations in grade A, continuous monitoring of critical pressure differentials, and justified frequencies for other areas.

Planning a cleanroom project?

Design, qualification, monitoring and team training: we support every stage of your controlled environments’ life cycle.