Cleanrooms: definition, standards and classes
A cleanroom is a room with controlled airborne particle concentrations. Temperature, humidity, pressure differentials and airflow are controlled as required. In French standards, the term is ‘salle propre’ (NF EN ISO 14644); ‘salle blanche’ is the common alternative. Both describe the same technical concept.
Two French terms for cleanrooms
‘Salle blanche’ is the historical French translation of cleanroom , popularised by electronics and microtechnology. ‘Salle propre’ is the term adopted by French standards and pharmaceutical guidance. Our French expertise pages use the standards terminology; this reference explains both terms.
ISO 14644 classes and GMP grades
ISO 14644-1 classifies cleanrooms by maximum airborne particle concentrations for specified particle sizes and occupancy states. EU GMP Annex 1 defines grades A to D for sterile medicinal product manufacture. The table below shows particle classification equivalences at rest; GMP grades also include additional requirements.
| ISO class (at rest) | GMP grade | Typical use |
|---|---|---|
| ISO 5 | Grade A | Critical zone: aseptic filling under unidirectional airflow |
| ISO 5 | Grade B | Background environment for a grade A zone outside an isolator. For isolators, the background should generally be at least grade C for open isolators and grade D for closed isolators, justified by risk assessment and documented in the CCS. |
| ISO 7 | Grade C | Less critical stages in the manufacture of sterile products |
| ISO 8 | Grade D | Less critical stages in the manufacture of sterile products |
References: NF EN ISO 14644-1 and 14644-2, EU GMP Annex 1 (2022 revision), and PIC/S PE 010 for medicinal product preparation in healthcare establishments.
From project to operation: key stages
- Design: target classifications, flows of personnel, materials and waste, and the air handling concept.
- Qualification: DQ, IQ, OQ, PQ — filter integrity testing, particle counting, air change rates, airflow visualisation and recovery time.
- Monitoring: particle and microbiological sampling plans, pressure differential monitoring and trend analysis.
- Ongoing compliance: periodic requalification, change control and operator training in cleanroom behaviour.
Frequently asked questions
What is the difference between ‘salle blanche’ and ‘salle propre’?
Both French terms refer to a cleanroom. ‘Salle blanche’ is common usage; ‘salle propre’ is the term used in NF EN ISO 14644. Both describe a room with controlled airborne particle concentrations, with temperature, humidity, pressure and airflow controlled as required.
How is a cleanroom classified?
ISO 14644-1 defines airborne particle concentration limits per cubic metre for specified particle sizes and occupancy states. In pharmaceutical manufacturing, these ISO classes are considered alongside grades A to D in EU GMP Annex 1.
How often should a cleanroom be requalified?
Requalification frequency is primarily risk-based. EU GMP Annex 1 sets maximum intervals: 6 months for grades A and B, and 12 months for grades C and D. Requalification is also required after changes assessed as significant through change control. This is supported by grade- and risk-appropriate monitoring: particles and microbiological monitoring throughout critical operations in grade A, continuous monitoring of critical pressure differentials, and justified frequencies for other areas.
Planning a cleanroom project?
Design, qualification, monitoring and team training: we support every stage of your controlled environments’ life cycle.